a4419e15cd
The previous harness only exercised S1F1/F11/F13/F19, S2F17/F29, S5F5, S7F19 — about 15% of what COMPLIANCE.md claims as ✅. Customers running secs_conformance against their tool got near-zero conformance signal on dynamic event reports, GEM 300, alarm management, exception recovery, terminal services, spool, and PP management. This expansion covers, in one sequential run: - Establish comms + identification (S1F13/F1) - Status / DVID / CEID / EC namelists + values (S1F11/F3/F21/F23, S2F29/F13) - Dynamic event reports: define / link / enable + readback paths (S2F33/F35/F37, S6F15/F19/F21) - All three remote-command forms (S2F41/F21/F49) - Equipment-initiated S6F11 observation triggered by RCMD=START - Trace init, limits attrs, spool reset + transmit (S2F23, S2F47, S2F43, S6F23) - Alarm management: list, list-enabled, enable (S5F5/F7/F3) - Exception recovery: request + abort (S5F13/F17) - PP load-inquire / list / request (S7F1/F19/F5) - Terminal display both directions (S10F3, S10F5) - E40 PJ create / monitor / command / dequeue (S16F11/F7/F5/F13) - E94 CJ create / command / delete (S14F9, S16F27, S14F11) - E87 carrier action / slot map / transfer / cancel (S3F17/F19/F25/F27) - E39 GetAttr (S14F1) - GEM compliance self-report (S1F19) Pass criterion is the spec-mandated reply function code, not any specific ACK value — CarrierIDUnknown / Denied_UnknownObject / PpidNotFound / Error are well-formed F-coded replies and count as protocol-conformant. This lets the harness run against any equipment without preloading state. 47 / 47 PASS against the in-repo demo server. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>