88205037ec
tests / build-and-test (push) Failing after 32s
Closes the small remaining hole in Alarm Management. S5F7 is header-only; S5F8 has the same wire shape as S5F6 (vector of <L,3 <B ALCD> <U4 ALID> <A ALTX>>) but only includes alarms whose enabled flag is set. Codegen handles both as a list_of with struct_name=AlarmListing; server pre-computes the per-row ALCD from (severity_category, active state) before passing the rows in. COMPLIANCE.md: Alarm Management Additional capability flips ✅. Tests: 78 cases / 454 assertions. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>