raphael cdf4049016 F2: EPT joined to EquipmentDataModel + server-side CEID emission
EquipmentDataModel now carries an EptStateMachine as a value member
alongside the other top-level state machines.  Server installs a
state-change handler that maps every EPT transition to a CEID emission
through the existing emit_event path:

  1100 NonScheduledTime    1103 Engineering
  1101 ScheduledDowntime   1104 Standby
  1102 UnscheduledDowntime 1105 Productive

CEIDs land in the 1100+ block to keep clear of the demo equipment.yaml
(100s/200s/400s) and E90 (900s).  Log lines include the dwell time of
the previous state so trace-level diagnostics show utilization without
extra tooling.

Application code drives transitions by calling model->ept.on_event(...);
the existing event-report machinery (subscription state, S6F11
batching, spool) gates wire emission so EPT events spool on offline
hosts like every other CEID.

Closes Tranche F — E116 Equipment Performance Tracking end-to-end.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>